Technical specs
NO. | Merchandise | Specs |
1 | Dimension and bodyweight | one hundred fifteen.9mmx95.5mmx69.3mm480g |
two | Exterior diameter of outlet | 27mm |
three | Exterior diameter of inlet | 27mm |
four | Driving system | Brush-significantly less, magnetic isolated design and style |
five | Materials of pump shell | Abdominal muscles,PES/SPS/PPS/PA66+thirty%GF (Optional) |
6 | Condition of use | Can repeatedly perform, submersible or land use (not self-priming) |
seven | Appropriate medium | Water, oil, or standard acid/ alkaline liquids (Pre-examination needed for particular liquid) |
eight | Max doing work temperature | 60ºC(for T sub-sequence) or 100ºC(for S/A sub-collection) |
nine | Energy consumption | 2.5W~48W(for T sub-collection) or 2.5W~86.4W(for S/A sub-collection) |
ten | Rated voltage | 12Vdc or 24Vdc |
eleven | Working voltage range | 5Vdc ~ 14Vdc or 5Vdc ~ 26Vdc |
twelve | Max load recent | 2.0A (for T sub-collection) or 4.5A(for S/A sub-series) |
thirteen | Max horizontal flow fee | 52L/MIN(for T sub-collection) or 60L/MIN(for S/A sub-series) |
14 | Max static lift | 3.5M(for T sub-collection) or 5M(for S/A sub-sequence) |
fifteen | Noise class | <40dB |
sixteen | Watertight course | IP68(appropriate for submersible installation) |
seventeen | Existence span | >30,000hrsIP68(suitable for submersible installation) |
eighteen | Power supply | Suited solar panel, batteries, adapter or other electricity source |
19 | CZPT perform | dry-operate defense, lock protection(CZPT function) |
20 | Energy regulation perform | Velocity adjustable by PWM sign, ~5V analog signal or potentiometer (capabilities are optional for customization) |
22 | Feature |
|
Pump Construction
CZPTtrical parameters (only for reference,parameters CZPT for certain needs)
Model No. | Voltage | Max load current | Max static elevate | Max stream rate | Energy usage |
V(dc) | A | M | L/H | w | |
DC50A-1225T | twelve | two. | 2.50 | 2000 | 24 |
DC50A-1225S | |||||
DC50A-1225A | |||||
DC50A-1235S | 12 | three.80 | 3.50 | 3000 | forty five.6 |
DC50A-1235A | |||||
DC50A-2435T | 24 | 2. | 3.50 | 3000 | forty eight |
DC50A-2435S | |||||
DC50A-2435A | |||||
DC50A-2450S | 24 | 3.60 | 5.00 | 3600 | 86.4 |
DC50A-2450A | |||||